Ceiling Cassette Type
- 118 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Ceiling Cassette Type
Auto Swing Control
This function is to swing the louver up and down automatically.
Soft-Dry Operation
The indoor fan speed is automatically set to the low, so the shift of the indoor fan speed is impossible because of
already being set to the best speed for Dry Operation by microcontroller control.
Cooling Mode Operation
When selecting the Cooling( ) Mode Operation, the unit will operate according to the setting by the remote con-
troller and the operation diagram is as following
Swirl Swing Control
Vane 2, 4 is almost vane closed while vane1, 3 is opened.
Vane 1, 3 and vane 2,4 turn over minutely
Intake Air Temperature
Thermo. On
(SET TEMPERATURE +0.5°C)
Thermo. Off
(SET TEMPERATURE -0.5°C)
More than More than
3 minutes 3 minutes
Selected Selected Selected
Speed Speed Speed
INDOOR FAN Low Low
The function of main control
Vane 2
Vane 1 Vane 3
Vane 4